Hi Nikolay, This is the issue I mentioned in "Critical worker threads liveness checking drawbacks" topic which I was expecting to be included to Ignite 2.7, but it was not. To workaround the issue, you should set DataStorageConfiguration#setCheckpointReadLockTimeout to 0.
Should we somehow announce it on the user-list or highlight on readme.io? чт, 27 дек. 2018 г. в 11:57, Nikolay Izhikov <nizhi...@apache.org>: > Hello, Igniters. > > I run into issue with critical system worker failure handler. > I just run `IgniteDataFrameSuite` and it terminates on random test. > My laptop doesn't have bleeding edge hardware, so tests can take > significant amount of time. > Looks like our watch dog too aggressive on development environment > > Can you please, help me. What should I do to configure or turn off watch > dog? > Should we relax it a little bit? At least for a test environment. > > Error message contains following message: > > ``` > [2018-12-27 11:40:23,597][ERROR][exchange-worker-#5547%grid-2%][root] > Critical system error detected. Will be handled accordingly to configured > handler [hnd=StopNodeOrHaltFailureHandler [tryStop=false, timeout=0, > super=AbstractFailureHandler [ignoredFailureTypes=UnmodifiableSet > [SYSTEM_WORKER_BLOCKED, SYSTEM_CRITICAL_OPERATION_TIMEOUT]]], > failureCtx=FailureContext [type=SYSTEM_WORKER_TERMINATION, err=class > o.a.i.IgniteCheckedException: Node is stopping: grid-2]] > class org.apache.ignite.IgniteCheckedException: Node is stopping: grid-2 > ``` >