Hi Stefan, Can you check how many BGP paths the GW router(s) has to the floating IP in question in steady state? If you are using an MX you can use "show route table xyz.inet.0". There should ideally be 2 paths learnt from 2 control-nodes.
-Nischal On Jul 1, 2015, at 7:48 AM, Stefan Andres <[email protected]> wrote: > Hi, > we have a setup with 3 contrail-control nodes. > We've seen that when we hard-power off on of those nodes, there is a > 25-45s packet loss to VM's floating IPs. > > I'd expect the floating IPs not to have any packet loss at all, since > the default BPG TTL should be 30s and in this time, the other > contrail-process should already have taken over. > > What's the concept there and how to tweak those settings? > > Regards, > Stefan > > _______________________________________________ > Dev mailing list > [email protected] > http://lists.opencontrail.org/mailman/listinfo/dev_lists.opencontrail.org _______________________________________________ Dev mailing list [email protected] http://lists.opencontrail.org/mailman/listinfo/dev_lists.opencontrail.org