https://issues.apache.org/jira/browse/PARQUET-484?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Liwei Lin updated PARQUET-484:
------------------------------
Description:
Below is documented in
https://github.com/Parquet/parquet-format/blob/master/LogicalTypes.md#decimal:
{quote} int32: for 1 <= precision <= 9
int64: for 1 <= precision <= 18; precision < 10 will produce a warning {quote}
This JIRA proposes to implement the `precision < 10 will produce a warning`
part.
was:
As is documented in
https://github.com/Parquet/parquet-format/blob/master/LogicalTypes.md:
int32: for 1 <= precision <= 9
int64: for 1 <= precision <= 18; precision < 10 will produce a warning
This JIRA proposes to implements the waring part.
> Warn when Decimal is stored as INT64 while could be stored as INT32
> -------------------------------------------------------------------
>
> Key: PARQUET-484
> URL: https://issues.apache.org/jira/browse/PARQUET-484
> Project: Parquet
> Issue Type: Improvement
> Components: parquet-mr
> Affects Versions: 1.8.0, 1.8.1
> Reporter: Liwei Lin
> Assignee: Liwei Lin
>
> Below is documented in
> https://github.com/Parquet/parquet-format/blob/master/LogicalTypes.md#decimal:
> {quote} int32: for 1 <= precision <= 9
> int64: for 1 <= precision <= 18; precision < 10 will produce a warning {quote}
> This JIRA proposes to implement the `precision < 10 will produce a warning`
> part.
--
This message was sent by Atlassian JIRA
(v6.3.4#6332)