Hey,
I do have an question about M-Bus devices. There are several things
which are quite specific to this standard.

When there is an read out request device answers with all values it does
have. Given my current (limited) knowledge about M-Bus, there is no way
to get single field. I believe it makes some sense since it is an bus
system where frame overhead matters.

Currently we miss a developer guidelines which would provide durection
for most common scenarios. I think in all other places it is rather
simple cause request items usually map to single (primitive) value in
the field device or complex type (user defined type) at most. That's why
we didn't need any major writing about above.

To put more context. Each reading of meter contains 0..N fields. Each
field have several points:
- Reported value (an int/decimal/string etc).
- Medium (ie. Electricity, Water, Gas)
- Function (instant value, min/max/avg value)
- Tariff
- Storage number (ie. actual or past month)

This means that for field request which is just "<slave-id>" we get N
fields whereas each field has several associated values. I guess that
some of values can be shifted to response metadata.
I need an advice how to handle this 1..N situation. I don't think we
have it in any other place. What driver should do?

Should it answer with:
- one field and struct with primitives
- one filed and struct of structs with all information
- multiple fields whereas answer for caller specified field will
contains List<String> indicating recognized field names.

I will also mention that for Wireless M-Bus situation is even more
complicated cause same device can report different set of fields. For
example there is one kind of frame every 15 seconds and another one
every 60 seconds.

Kind regards,
Łukasz