I been thinking of issues I so far found within plc4x api and one of them is field-centric approach which bounds client to think in the same way. Yet, some protocols think in different categories and there field-centric work turns out into a nightmare.

For example within CANopen it is possible to read an variable length array of values through SDO transfer (ie. object 0x5000). Yet, in order to do that using plc4x apis it is necessary to construct a first call (0x5000/0x0) which reads array length and then goes over sub-indexes (0x5000,0x1..N). This is not a big burden, but as soon as same structure is used across multiple places amount of code to orchestrate array retrieval grows. More over, I think that everyone who will get into CANopen and SDO read outs will sooner or later copy this logic to his code. I thought if driver could get it better, but I don't think it would without .. object dictionary which is specific to CANopen. Not sure of other protocols, as they seem to be rather fine with field level access, but I don't think that this measure fits all is right. Looking at more complex protocols such as BACnet it is indeed possible to make a client which rely on fields, but it will turn caller code into a mess forcing further structuring of layers above plc4x just to reflect protocol philosophy. On other hand we have a M-Bus which in most of the cases works by returning all device measurements at one shot breaking the 1:1 mapping between request and reply item. We haven't made a consensus how it could be addressed, but to me this protocol (as well as WM-Bus) is not well fit to keep above contract.

Because of rather bad code I made in 2020 while working on first CANopen binding for openHAB I started to re-structure it and improve its internal design in 2021. A bit of time have passed and I am again in a place where I don't think my work back then was going into right direction. First of all, I extracted CoNode, CoConnection and several more interfaces, but still at interaction level it does not involve object dictionary describing device abilities which is crucial in quick bootstrapping of integration. As I am preparing myself to another attempt to untie connectorio canopen binding code from specific vendor flavor I had to implement, I am back to the problem of 1) where to put higher level API 2) how to structure it. While I currently do not running bacnet not profinet driver from plc4x I do smell very similar troubles there, especially with bacnet objects (ie. schedules) and profinet configs which reflect GSDML and other descriptors out there. Obviously we can always make everything a field, but will it make a sense?

_just an idea (tm)_
My brief thinking is about possibility to define an "ExtendedDriver<Rq,Rp>" interface (rq - request container, rp - response container), which would provide us a generic purpose request/response logic as well as subscription stuff. I am sure it will be a bunch of work, however in some ways this might feel easier to implement than mapping everything to fields and back. This could be compared to a stored procedure call within JDBC api which is usually vendor specific. Caller of such procedure usually has to handle result according to database provider. In our case through definition of request/response container we could at least enforce some basic contract between various equipment. It would let us also to define a higher level types (subset of PlcObject convertible to a PlcStruc's?) to interact:

ExtendedDriver<CANopenReqest, CANopenResponse> extendedDriver;
// assuming CompletableFuture as outcome
// maybe request could optionally have a SDO entry mapper?
extendedDriver.read(new CANopenSDORequest(0x5000, CANopenType.ARRAY))
  .whenComplete((CANopenResponse r, Throwablee ) -> {
    // CANopen specific logic, but well, it is interacting with CANopen
    // and this code knows what to do with it
    MappedData[] data = r.getArray(/*maybe SDO mapper here?*/);
    // CANopenObject o = r.getPlcObject() ??
  })

I don't really have any time frame nor pursue to work on that topic, however I wanted to bring it up as I feel we could improve (simplify till some degree) device interaction in some cases. Maybe not all, but these which are more "object oriented" for sure. I want also to give myself enough of time to think of how to make a first attempt without making it too dumb nor too complicated. Above, I think, could also be used for discovery of symbols or objects through connections which rely on the same transport as driver itself. For example Beckhoff symbols are just read from index within TCP connection we make to PLC. Also, if we look at udp discovery in BACnet, its just one of operations defined in protocol. Both give us different outcome, yet they do work over connection we already made. Obviously it can be mapped through connection metadata. While it would fit into this API (which is not used anywhere I guess), this approach also gives us a trouble of mapping all into plc fields. With an explicit contract of field retrieval we are forced to serialize everything to a field, even if it does not reflect how given automation system work. Also our field definitions will get more and more complicated and harder to keep in sync between languages.

Looking forward to your comments on above or counter ideas. Till summer season I suppose. :-)