Hi, Definitely +1, it would be great to be able to have multiple connections/protocols handled in a consistent way. PROFINET is a prime example of one that would benefit, as it uses multiple protocols (LLDP, DCP, PNIO) as well as multiple end devices.
Let me know if I can help. Ben On Sat, May 6, 2023 at 1:20 PM Lukas Ott <[email protected]> wrote: > +1 for building a more generic solution for multi-connections as it helps > for PROFINET and ADS as well > > Am Fr., 5. Mai 2023 um 15:17 Uhr schrieb Christofer Dutz < > [email protected]>: > > > Hi all, > > > > while going through Cesar’s changes I noticed that he actually addressed > > something I keept on avoiding ;-) ... Multi-Connections. I know I needed > > them for PROFINET (Raw base transport and UDP config) as well as ADS (TCP > > base transport and UDP config) ... I solved the problem by implementing > the > > UDP stuff manually, completely avoiding Netty .. but I think it would be > > more in the spirit of PLC4X to do it in a cleaner way ... as Cesar did > it. > > > > However, Cesars version is hard-coded for S7 and S7HA. I would suggest to > > build a more generic solution ... what do you folks think? > > > > Chris > > >