On Fri, 2002-05-03 at 10:58, Alex Judd wrote:
> Thanks Bruno - good to see your full name is now on your emails :)
> 
> > set "retry = true" on at2 smsc group (and I'd advise you to use it in 
> > every smsc group) to force kannel to reopen at2 connection.
> > 
> > If you want to "ping" the modem and keep the connection alive, 
> > set "keepalive = 60" (seconds) too and if you have motorola manual
> > (or try yourself and tell us if it works), set 
> > keepalive-cmd = "AT+CBC;+CSQ"
> > on modems.conf, near your groups=modems, id=motorola (uhm, I don't see
> > any motorola, which at group are you using)
> 
> See my patch earlier (+CMTI support) which includes the new group for the 
> Motorola P7389i and support for it to be added to CVS (unless someone has 
> done already???).
> 
> I guess here we could use something really simple like an ATI4 or similar 
> as a 'do something' comand however your battery level one is quite nice.

If keepalive is set, kannel would just send 'AT', because it's the 
default "keepalive command" 

but you can change it on modems.conf. I'm using those commands because 
sometimes my modem got out of network and I needed to reset it. I was
thinking in using those values to do a automatic reset patch, but the
modem no longers gets out of network and I forgot about the patch...


> 
> Alex
> 
> -- 
> Alex Judd
> http://www.skywire.co.uk
> 
> 



Reply via email to