Hi Soren, here is my specification of siemens-ota (seo), I use:
- - - - 5 [2F 2F 53 45 4F] - Identifier ASCII "//SEO" 1 [01] - Version 1 2 [67 00] - DataSize = 103 Byte 4 [79 07 00 00] - Referenz-ID 2 [01 00] - ActPacketNumber = 1 2 [08 00] - NumberOfPackets = 8 4 [EE 02 00 00] - ObjectSize = 750 Byte 4 [03 62 6D 70] - ObjectType = 3 "bmp" 13 [OC 4F 70 65 72 61 74 6F 72 2E 62 6D 70] - ObjectName = 12 "Operator.bmp" 103 [70 42 4D ...] Data of the Bitmap in BMP-Format = 140 Bytes (if the last sms is less, you have to fill out with 00 (zero). - - - - If you have a look on my seo-example, here I split and tell you more about the first sms: 2F2F53454F = //SEO 01 = Seo-Version 1 6600 = my Data-Size is 102 Byte 2664673E = my ID of the seo-sms (must be the same in every sms) 0100 = message-number 1 0500 = of 5 messages C3010000 = 451 byte data-size (here from my midi) 036D6964 = 3 number of letters / BMP 0D756E646572626572672E6D6964 = 13 number of letters / UNDERBERG.MID 4D546864000000060001000201E04D54726B0000004700FF0314417564696F496E7374202031 2A6B6F706965727400FF01124445564943453D47454E4552414C2E4D445600FF580404022408 00FF5902000000FF5103087A2300FF2F004D54726B0000015E00 = DATA of the midifile - - - - Now I want to send this seo-string to my kannel-gateway, as udh-string - but it only works with ems-messages :-(( no siemens. Thanks for your help! -- Best regards, Dominik mailto:[EMAIL PROTECTED]