You need to set the History.KeepAll and Reliability.Reliable to keep all the 
samples. Keep in mind you need to ensure you have enough resources.

Brian


From: developer-boun...@opensplice.org 
[mailto:developer-boun...@opensplice.org] On Behalf Of Rakesh pawar
Sent: Thursday, September 08, 2011 8:05 AM
To: developer
Subject: [OSPL-Dev] Recovering lost samples at the subscriber side

Hello,

In the Chatter example, if I run the Chatter(Pub) and MessageBoard (Sub), I 
terminate the message board and again reconnect after a while, I am receiving 
the current samples being published. How can I receive the samples published 
during the time when the MessageBoard was terminated. Do I need to set the 
History and Reliability Qos for this purpose? I have added <reconnect="true"> 
in the ospl.xml. Is there any other QOS i need to set to receive the lost 
samples ?




--

Cheers !
Rakesh Pawar

_______________________________________________
OpenSplice DDS Developer Mailing List
Developer@opensplice.org
Subscribe / Unsubscribe http://dev.opensplice.org/mailman/listinfo/developer

Reply via email to