I am wondering about other experiences with fuel for the limbach motors. We have been running almost exclusively on 100LL avgas and occasionally on a 50/50 blend with 97 mogas when avgas is difficult. Has anyone been running mostly on high mogas blends and if so how well do components like exhaust valves last? Rob (VH-GYT)
PO Box 129, Lawson, NSW, 2783. mobile 0429 493828 ............................................. --- On Thu, 8/9/11, Rob Thompson <[email protected]> wrote: From: Rob Thompson <[email protected]> Subject: Re: [DOG mailing list] Fuel Tank To: [email protected] Received: Thursday, 8 September, 2011, 7:00 PM I was thinking about making a cardboard "mock up" tank from the plans then checking the fit. When all is OK then use the cardboard panels as templates to guillotine the aluminium sheet. Our fibreglass tank is a very tight fit in the back compartment. I am a little concerned that if the aluminium tank is also a tight fit that a very slight error in measurements and/or construction could be a major problem. Rob (GYT) PO Box 129, Lawson, NSW, 2783. phone 02 47592307 mobile 0429 493828 ............................................. --- On Wed, 7/9/11, Nigel Baker <[email protected]> wrote: From: Nigel Baker <[email protected]> Subject: [DOG mailing list] Fuel Tank To: "DOGS" <[email protected]> Received: Wednesday, 7 September, 2011, 11:20 PM Hi All. This post is for those in Australia with H36 Aircraft. For those who have the FRP fuel tank which needs inspection every annual or 100hours note it expires at 3000 hours. I have a copy of the drawings for the alloy replacement fuel tank. This will require and OZ E.O. being raised for the production of the same and welded by a CASA certified welder. I have spent some time tracing over the drawings as they are old blue prints and working through the interpretation with German speaking engineers to get then to the point of being able to be used here. There are some tooling issues which will need to be addressed in an EO for an alternative to the fabrication method on the drawings. Thus before Rob and I go down this this path to produce 2 tanks is there anyone else on the list interested in cost sharing for an upgrade. I will happily do the change just to avoid the AD each year. Also I have had a quote from Diamond. To put things in perspective the quote is less than a new set of clear view panels and rails for the canopy. If there are enough interested I can negotiate a better price. Being realistic with the way the exchange rate is the price isn’t bad and if we can get a discount for volume it will be even better. From Diamond. “P/N for the tank is DV2-2811-00-00, sales price € 635,18 for one piece We do not have them on stock. If you are going to order them the external supplier has to produce them new for you.” Cheers. Nige.