hi Robert,
(your msg & mine crossed)
That doesn't help me solve it either. It's in the same ckt as R-45,
essentially, shouldn't see any action exc. on xmt. The diode, D12 in series
with it, is most likely also bad. Again, it looks like a surge of voltage
somehwere it didn't belong.
73,
Al
----- Original Message -----
From: "Robert Lawson" <[EMAIL PROTECTED]>
To: "Al Parker" <[EMAIL PROTECTED]>; <[EMAIL PROTECTED]>
Sent: Wednesday, July 30, 2003 4:14 PM
Subject: Re: [drakelist] TR-4C
> Sorry for the further bandwidth but R45 2 ohm is good. I should have
listed the 47
> ohm R189 in the relative output/plate current meter shown on the extreme
right of the
> fold out schematic.
>
> Thanks fellows.
>
> Robert
----------------------------------------------------------------------