John -


The TR-7 uses a "real" relay, and should be able to key the SB-200 easily. The relay is similar to the one used in the 4 Series and the contacts are rated at 3A maximum and 1000V breakdown. The problem is with the (primarily) Japanese rigs that use small reed relays for amplifier keying.

73, Garey - K4OAH
Atlanta

john wrote:
Is anyone using this combination?

I wonder if it's advisable to use an external relay to control
the amp, or whether the TR7 switching can handle it as-is?

Sage advice of the Drakelist greatly appreciated!!!
John

----------------------------------------------------------------------