If my memory serves me correctly....A variac is a variable "autotransformer."

Autotransformers have a single winding and, therefore, can not be used for isolation purposes.

73,
Jay/AF2C



At 01:55 PM 3/26/06 -0500, you wrote:

One word of caution. Some folks are under the impression that a variac also acts as an isolation transformer. It is not and offers no isolation at all, so if you are working with an AC/DC (transformerless) set, safety dictates the use of an isolation transformer with or without the variac.

73, 

John,  W4AWM


No virus found in this incoming message.
Checked by AVG Anti-Virus.
Version: 7.1.385 / Virus Database: 268.3.1/292 - Release Date: 3/24/06


No virus found in this outgoing message.
Checked by AVG Anti-Virus.
Version: 7.1.385 / Virus Database: 268.3.1/292 - Release Date: 3/24/06