Morning all,
Deep into my new (to me) TR-7, I am attempting to align this unit.
I have a very accurate counter / analyzer (Aeroflex-IFR), and am attempting to 
align the 40Mhz and the 53.695Mhz oscillators.
After setting the 10.00 Volts, I moved on to the 40Mhz and 53.695Mhz 
oscillators.
When I attempt to align the 40Mhz, and approach 40Mhz with L1001, all seems 
well so I believe the coil is good but I lose lock as I approach 40Mhz.  
Closest I can get is 1.07kHz low.  I do get about 1.9kHz swing in the 
adjustment of the slug.
Second...when attempting to adjust the 53.695, I get close but cannot seem to 
get there.  I am low 2.441kHz, as the closest I can get.

While I believe the crystals are both off, is there any hints and kinks (adding 
caps, etc?) to get this back in alignment?  

Thoughts?

Warm Regards,  Frank, KG9H