Hi! Homework complete!

Yes, Garey was correct !!!  The RF Output meter was not sensitive
enough to balance the Balanced Modulator and I think I followed his
procedure!

I connected a Drake 2-C, with the mute cable and the antenna cable
connected to the rx output of the T-4XB and then "spotted", so that
the RX and the TX were at the same frequency. The 2-C was set at with
the function EXT-mute. Then, with the "Transceive function of the
T-4XB set at SPOT", I tuned up in the TUNE position on LSB, then
switched to CW and closed PTT. Then I listened on the 2-C for the
"suppressed" carrier.  Set AVC to FAST, and adjusted the Carrier
Balance control (10 turn pot) and C6 for minimum S-Meter reading. I
could see the difference moving the Carrier Balance pot on the RX
s-meter !!!.

While the Carrier pot can be moved by 10 turns or so, C-6 seemed to
move by just 90 degrees (a quarter of turn). I didn't want to force it
as I was afraid to break it. Do you know if C-6 moves just by that
little?

73,

Frank IZ2OOS

_______________________________________________
Drakelist mailing list
[email protected]
http://mailman.zerobeat.net/mailman/listinfo/drakelist

Reply via email to