I am bringing back to life 2 each T-4XC's and 2 each AC-4's that  have been 
idle for over 15 yr. Both units are stock. I checked all the  electrical 
and mechanical connections for security. Checked and cleaned the  switches. 
Tested the tubes and reseated them with DeOxit. I checked all  resistance 
measurements with the Resistance Chart. I connected a Dummy Load.  Over a 
period 
of 3 days I slowly brought up the combinations with a Variac. At  100 vac 
the high voltages are +650 and +250 vdc. I adjusted the Bias to .07  amps. 
Using the Tune-up procedures, I go to Tune, rotate the gain control, and I  
get no meter movement on either T-4XC.  Question: Do I have to connect a  R4C 
to the T-4XC to get output. Right now it's just the T-4XC operating.   Best 
Regards to the Group.   Doug