After trying several pairs of 6JB6 tubes with similar behavior ( PA current 
very sensitive to drive control position), concluded the trouble couldn't be 
the PA tubes.  Swapped the driver tube with one in my T-4XB, now the plate 
current behaves normally, that is increases smoothly with increasing drive 
rather than jumping sharply from about 150 ma to 250 ma. 

I haven't checked to see whether the T-4XB now behaves strangely using the 
driver from the T-4X , and the driver tests good in my old Eico tube tester.  
But, have always heard that a tube testing good in a simple emmission tester 
doesn't mean it will work properly in circuit. 

Any thoughts? 

73, Curt KB5JO