Paul -

Sounds like the dreaded 'TR-7 Disease'! :-) Multiple, seemingly unrelated problems from a rig that 'worked 100% when put away'.

Easiest fix is to just reseat all cards and connectors. Lift each card up slightly and push back down. You MAY get away with just the rearmost 2nd IF/AF board since at least two of your symptoms are indications. A little DeoxIT will help a little, but is a LOT more work! Personally, I don't think the improvement is worth the work. I DeoxIT any card that is removed for other reasons, but not it a case like this.

There just isn't enough voltage or current in these modern (read solid state) radios to break through even the slightest corrosion on contacts. Gold plated contacts throughout would help, but was/is not cost competitive. For reliability, SS gear should have the absolute minimum number of interconnects. Not having ANY voltage on these, especially the ones with dissimilar metal to metal contact, forms a nice layer of insulation even in ideal storage conditions.

73, Garey - K4OAH
Glen Allen, VA

Drake 2-B, 2-C/2-NT, 4-B, C-Line&
TR-4/C Service Supplement CDs
<www.k4oah.com>


Drakedude wrote:
Took my TR7 that was in temp controlled storage for about one year and found I have no receive. Radio worked 100% when put away in closet. TX works fine,all modes,full output. I get meter deflection when I rotate RF gain control . I have very weak audio of TX signals,no meter deflection when a strong signal ( compared to another recvr same antenna) Filter selection works,as you cab hear bandwidth narrow with narrow filter. PBT works good also.
I removed relay & cleaned contacts to no avail.
All voltages at 10 volts or slightly lower on reg. board.

Any thoughts?

Tnx in advance

Paul AD3G


_______________________________________________
Drakelist mailing list
[email protected]
http://mailman.zerobeat.net/mailman/listinfo/drakelist

Reply via email to