On Thu, 27 Jan 2011 13:09:40 EST, [email protected] wrote:

>Thanks to everyone for their replies on the light bulb issue. I will look 
>further into the thermistor application. I was concerned about the statement 
>about the power supply regulation when using a thermistor. Any additional 
>comments about that issue. I don't want to create any additional problems by 
>trying to solve this one.         

I don't think it's an issue if the NTC is properly sized. I installed one from
a PC power supply in my AC-4, and didn't notice any problems - although I
didn't take any actual measurements. Also, my PS-7, but there it's rather a
moot point since it is a regulated supply. For the truly concerned, a
time-delay relay circuit can be devised to bypass the NTC after a few seconds.

73

-Jim


--
Ham Radio NU0C
Lincoln, Nebraska, U.S.S.A.
TR7/RV7/R7A/L7, TR6/RV6, T4XC/R4C/L4B, NCL2000, SB104A, R390A, GT550A/RV550A, 
HyGain 3750, IBM PS/2 - all vintage, all the time!

"Give a man a URL, and he will learn for an hour; teach him to Google, and he 
will learn for a lifetime."

HyGain 3750 User's Group - http://groups.yahoo.com/group/HyGain_3750/
http://incolor.inetnebr.com/jshorney
http://www.nebraskaghosts.org



_______________________________________________