Paul - Most likely is leaky C115.
73, Garey - K4OAH Glen Allen, VA Drake 2-B, 2-C/2-NT, 4-A, 4-B, C-Line and TR-4/C Service Supplement CDs <www.k4oah.com> Paul Gerhardt wrote:
This is a minor issue but is there a cure for excessive 'bouncing' of the S-Meter? It seems to work normally but with say an S9 signal it seems to 'bounce' excessivly. Maybe the AVC is not as Slow as it should be, it is working though, OR is it possible that the Meter itself has lost some of its 'damping' ability?
_______________________________________________ Drakelist mailing list [email protected] http://mailman.zerobeat.net/mailman/listinfo/drakelist