On 18/08/2026 10:19, Wim de With wrote:
> On Tue, Aug 18, 2026 at 09:34:14AM +0200, Krzysztof Kozlowski wrote:
>> On Sun, Aug 16, 2026 at 12:57:04PM +0200, Wim de With wrote:
>>> +static int ocp8178_bl_enable_onewire(struct ocp8178_bl *ocp8178)
>>> +{
>>> +   u64 start, duration;
>>> +
>>
>> It seems you re-implemented one-wire interface instead of using w1. Why?
>> What sort of one-wire bus/interface is this?
>>
>> Best regards,
>> Krzysztof
>>
> 
> It's not actually w1, it's just some non-standard protocol that the
> vendor confusingly calls '1-Wire' in the datasheet, to distinguish it
> from the PWM mode.

OK

Best regards,
Krzysztof