On Tue, Aug 18, 2026 at 09:34:14AM +0200, Krzysztof Kozlowski wrote:
> On Sun, Aug 16, 2026 at 12:57:04PM +0200, Wim de With wrote:
> > +static int ocp8178_bl_enable_onewire(struct ocp8178_bl *ocp8178)
> > +{
> > +   u64 start, duration;
> > +
> 
> It seems you re-implemented one-wire interface instead of using w1. Why?
> What sort of one-wire bus/interface is this?
> 
> Best regards,
> Krzysztof
> 

It's not actually w1, it's just some non-standard protocol that the
vendor confusingly calls '1-Wire' in the datasheet, to distinguish it
from the PWM mode.

Regards,
Wim