Hi, This fixes garbled compressed scanout on my device (Moto G10, SM4250) after display power cycling. MDSS needs the DISPCC AHB clock before the DPU child resumes, so this adds it to the binding and shared SM6115 clock list. I tested this on 7.2.9 and power-cycled the display 20 times.
Michael McAllister (2): dt-bindings: display: msm: sm6115-mdss: Add missing AHB clock arm64: dts: qcom: sm6115: Add missing MDSS AHB clock .../devicetree/bindings/display/msm/qcom,sm6115-mdss.yaml | 5 ++++- arch/arm64/boot/dts/qcom/sm6115.dtsi | 3 ++- 2 files changed, 6 insertions(+), 2 deletions(-) base-commit: d053e38e614fb2e383b298ce8fc308a780d7f209 -- 2.39.5