Now that drivers/i2c/busses/i2c-cht-wc.c uses
"input-current-limit-from-supplier" instead of "extcon-name" the last
user of the bq24190 extcon code is gone, remove it.

Signed-off-by: Hans de Goede <hdego...@redhat.com>
---
 drivers/power/supply/bq24190_charger.c | 107 ---------------------------------
 1 file changed, 107 deletions(-)

diff --git a/drivers/power/supply/bq24190_charger.c 
b/drivers/power/supply/bq24190_charger.c
index 1f6424f0772f..0376de6d8e70 100644
--- a/drivers/power/supply/bq24190_charger.c
+++ b/drivers/power/supply/bq24190_charger.c
@@ -11,7 +11,6 @@
 #include <linux/module.h>
 #include <linux/interrupt.h>
 #include <linux/delay.h>
-#include <linux/extcon.h>
 #include <linux/of_irq.h>
 #include <linux/of_device.h>
 #include <linux/pm_runtime.h>
@@ -155,9 +154,6 @@ struct bq24190_dev_info {
        struct device                   *dev;
        struct power_supply             *charger;
        struct power_supply             *battery;
-       struct extcon_dev               *extcon;
-       struct notifier_block           extcon_nb;
-       struct delayed_work             extcon_work;
        char                            model_name[I2C_NAME_SIZE];
        bool                            initialized;
        bool                            irq_event;
@@ -1530,75 +1526,6 @@ static irqreturn_t bq24190_irq_handler_thread(int irq, 
void *data)
        return IRQ_HANDLED;
 }
 
-static void bq24190_extcon_work(struct work_struct *work)
-{
-       struct bq24190_dev_info *bdi =
-               container_of(work, struct bq24190_dev_info, extcon_work.work);
-       int error, iinlim = 0;
-       u8 v;
-
-       error = pm_runtime_get_sync(bdi->dev);
-       if (error < 0) {
-               dev_warn(bdi->dev, "pm_runtime_get failed: %i\n", error);
-               pm_runtime_put_noidle(bdi->dev);
-               return;
-       }
-
-       if      (extcon_get_state(bdi->extcon, EXTCON_CHG_USB_SDP) == 1)
-               iinlim =  500000;
-       else if (extcon_get_state(bdi->extcon, EXTCON_CHG_USB_CDP) == 1 ||
-                extcon_get_state(bdi->extcon, EXTCON_CHG_USB_ACA) == 1)
-               iinlim = 1500000;
-       else if (extcon_get_state(bdi->extcon, EXTCON_CHG_USB_DCP) == 1)
-               iinlim = 2000000;
-
-       if (iinlim) {
-               error = bq24190_set_field_val(bdi, BQ24190_REG_ISC,
-                                             BQ24190_REG_ISC_IINLIM_MASK,
-                                             BQ24190_REG_ISC_IINLIM_SHIFT,
-                                             bq24190_isc_iinlim_values,
-                                             
ARRAY_SIZE(bq24190_isc_iinlim_values),
-                                             iinlim);
-               if (error < 0)
-                       dev_err(bdi->dev, "Can't set IINLIM: %d\n", error);
-       }
-
-       /* if no charger found and in USB host mode, set OTG 5V boost, else 
normal */
-       if (!iinlim && extcon_get_state(bdi->extcon, EXTCON_USB_HOST) == 1)
-               v = BQ24190_REG_POC_CHG_CONFIG_OTG;
-       else
-               v = BQ24190_REG_POC_CHG_CONFIG_CHARGE;
-
-       error = bq24190_write_mask(bdi, BQ24190_REG_POC,
-                                  BQ24190_REG_POC_CHG_CONFIG_MASK,
-                                  BQ24190_REG_POC_CHG_CONFIG_SHIFT,
-                                  v);
-       if (error < 0)
-               dev_err(bdi->dev, "Can't set CHG_CONFIG: %d\n", error);
-
-       pm_runtime_mark_last_busy(bdi->dev);
-       pm_runtime_put_autosuspend(bdi->dev);
-}
-
-static int bq24190_extcon_event(struct notifier_block *nb, unsigned long event,
-                               void *param)
-{
-       struct bq24190_dev_info *bdi =
-               container_of(nb, struct bq24190_dev_info, extcon_nb);
-
-       /*
-        * The Power-Good detection may take up to 220ms, sometimes
-        * the external charger detection is quicker, and the bq24190 will
-        * reset to iinlim based on its own charger detection (which is not
-        * hooked up when using external charger detection) resulting in
-        * a too low default 500mA iinlim. Delay applying the extcon value
-        * for 300ms to avoid this.
-        */
-       queue_delayed_work(system_wq, &bdi->extcon_work, msecs_to_jiffies(300));
-
-       return NOTIFY_OK;
-}
-
 static int bq24190_hw_init(struct bq24190_dev_info *bdi)
 {
        u8 v;
@@ -1636,7 +1563,6 @@ static int bq24190_probe(struct i2c_client *client,
        struct device *dev = &client->dev;
        struct power_supply_config charger_cfg = {}, battery_cfg = {};
        struct bq24190_dev_info *bdi;
-       const char *name;
        int ret;
 
        if (!i2c_check_functionality(adapter, I2C_FUNC_SMBUS_BYTE_DATA)) {
@@ -1668,25 +1594,6 @@ static int bq24190_probe(struct i2c_client *client,
                device_property_read_bool(dev,
                                          "input-current-limit-from-supplier");
 
-       /*
-        * Devicetree platforms should get extcon via phandle (not yet 
supported).
-        * On ACPI platforms, extcon clients may invoke us with:
-        * struct property_entry pe[] =
-        *   { PROPERTY_ENTRY_STRING("extcon-name", client_name), ... };
-        * struct i2c_board_info bi =
-        *   { .type = "bq24190", .addr = 0x6b, .properties = pe, .irq = irq };
-        * struct i2c_adapter ad = { ... };
-        * i2c_add_adapter(&ad);
-        * i2c_new_device(&ad, &bi);
-        */
-       if (device_property_read_string(dev, "extcon-name", &name) == 0) {
-               bdi->extcon = extcon_get_extcon_dev(name);
-               if (!bdi->extcon)
-                       return -EPROBE_DEFER;
-
-               dev_info(bdi->dev, "using extcon device %s\n", name);
-       }
-
        pm_runtime_enable(dev);
        pm_runtime_use_autosuspend(dev);
        pm_runtime_set_autosuspend_delay(dev, 600);
@@ -1747,20 +1654,6 @@ static int bq24190_probe(struct i2c_client *client,
                goto out_sysfs;
        }
 
-       if (bdi->extcon) {
-               INIT_DELAYED_WORK(&bdi->extcon_work, bq24190_extcon_work);
-               bdi->extcon_nb.notifier_call = bq24190_extcon_event;
-               ret = devm_extcon_register_notifier_all(dev, bdi->extcon,
-                                                       &bdi->extcon_nb);
-               if (ret) {
-                       dev_err(dev, "Can't register extcon\n");
-                       goto out_sysfs;
-               }
-
-               /* Sync initial cable state */
-               queue_delayed_work(system_wq, &bdi->extcon_work, 0);
-       }
-
        enable_irq_wake(client->irq);
 
        pm_runtime_mark_last_busy(dev);
-- 
2.13.3

_______________________________________________
devel mailing list
de...@linuxdriverproject.org
http://driverdev.linuxdriverproject.org/mailman/listinfo/driverdev-devel

Reply via email to