Dear DuMuxes, I used to use MPNC code to simulate two phase four component system. Now I want to modify 2p2c by adding two more components. I have done blow steps: 1- Fluidsystem for four components and two phases 2- Modifying NumEq, NumComponents 3-Initial and boundary condition for new components assigned to primary variables 4-Modifiying LocalResidual calculation for new components, i.e: eqIdx= ...
5-Modifying Model class switch criteria w.r.t. mole fraction of new components 6-Modifying FluxVariables to compute mole/mass fraction gradient for the new components. 7-Modifying VolumeVariables->completeFluidState for the case of bothPhases presence to use Miscible2pNcComposition instead of MiscibleMultiphaseCompostion. After all I get the error message: 'ILU failed to invert matrix block... matrix M is singular' Just wanted to ask you what are the possible causes of this error message? Thank you very much, Regds, Mojdeh
_______________________________________________ Dumux mailing list [email protected] https://listserv.uni-stuttgart.de/mailman/listinfo/dumux