> -----Original Message-----
> From: Fujinaka, Todd <[email protected]>
> Sent: Thursday, May 05, 2022 7:23 AM
> To: [email protected]; [email protected]
> Subject: Re: [E1000-devel] [igbvf] Accessing PTP clock from a Virtual Function
> 
> Not everything in the hardware is enabled in the software. We do not appear to
> be using the register you mention.
> 
> I have been told by those more familiar with PTP that the Time Sync registers 
> are
> in chapter 8.16 and are only accessible through the PF.
> 
> Todd Fujinaka
> Software Application Engineer
> Ethernet Products Group
> Intel Corporation
> [email protected]
> 
> -----Original Message-----
> From: [email protected] <[email protected]>
> Sent: Thursday, May 5, 2022 5:41 AM
> To: [email protected]
> Subject: [E1000-devel] [igbvf] Accessing PTP clock from a Virtual Function
> 
> Hello,
> 
> I'd like to access the PTP timer of an i350T2V2 from a VF. The Datasheet 
> (Rev. 2.6)
> states in section 7.8.2.12.2 that "VMs have access to the real time clock 
> register".
> But the only timer-related register which is mapped to a VF I could find is 
> the
> free-running timer (VTFRTIMER at 0x1048). So I'm kind of confused.
> 
> P.S. yes I know that there is ptp_kvm module, but it uses hypercalls which 
> I'd like
> to avoid.
> 
> Thanks a lot,
> 
> Bjarne
> 
> 

Todd is correct, the Time Sync registers are unfortunately not accessible to 
the VF.

Thanks,
Jake