>-----Original Message-----
>From: Aleksey Chudov [mailto:[email protected]]
>Sent: Tuesday, April 03, 2012 7:49 AM
>To: [email protected]
>Subject: [E1000-devel] Intel 82574L rx_short_length_errors
>
>
>Then I tied to insert in one server additional NIC 82576 connected to
>the
>same switch through the same patch cable and errors completely
>disappeared.
>

Do the errors on the 82574 disappear when the 82576 is installed or is it that 
the errors don't appear on the 82576? 

Thanks,

Carolyn