82575 only has software timestamping capability and it doesn't
have PTP Hardware Clocks. Therefore, -1 has to be specified
to the phc_index for ethtool's get_ts_info, otherwise a wrong
value will be set to the phc_index.

Signed-off-by: Ken ICHIKAWA <[email protected]>
---
 drivers/net/ethernet/intel/igb/igb_ethtool.c | 1 +
 1 file changed, 1 insertion(+)

diff --git a/drivers/net/ethernet/intel/igb/igb_ethtool.c 
b/drivers/net/ethernet/intel/igb/igb_ethtool.c
index 1df0237..d9bd614 100644
--- a/drivers/net/ethernet/intel/igb/igb_ethtool.c
+++ b/drivers/net/ethernet/intel/igb/igb_ethtool.c
@@ -2360,6 +2360,7 @@ static int igb_get_ts_info(struct net_device *dev,
                        SOF_TIMESTAMPING_TX_SOFTWARE |
                        SOF_TIMESTAMPING_RX_SOFTWARE |
                        SOF_TIMESTAMPING_SOFTWARE;
+               info->phc_index = -1;
                return 0;
        case e1000_82576:
        case e1000_82580:
-- 
1.8.2.1



------------------------------------------------------------------------------