On Wed, Apr 01, 2015 at 19:57:30 +0200, Ronald van der Pol wrote:

> On Wed, Apr 01, 2015 at 09:52:35 -0700, Jesse Brandeburg wrote:
> 
> > I think the piece you're missing is that you need to run the QCU (QSFP+
> > Configuration Utility) to switch the port from 40G to 4x10 mode.
> 
> Thanks. I now have ens5f[0-3]. But also:
> [  329.351781] i40e 0000:81:00.0 ens5f0: the driver failed to link because an 
> unqualified module was detected.
> on all ports. I guess the breakout cable is in the wrong port (we have
> the 2-port version with an Intel breakout and a 3rd party QSFP).
> 
> I'll put the breakout cable in the other port tomorrow.

Running QCU did the trick. It is now working. Thanks.