REF: https://bugzilla.tianocore.org/show_bug.cgi?id=1225
According to UEFI spec, the string expression of UTF8 vendor device node should be displayed as: VenUtf8(). Current code display it as: VenUft8() by mistake when convert device path node to text. This commit is to fix this bug. Cc: Ruiyu Ni <[email protected]> Cc: Michael D Kinney <[email protected]> Cc: Liming Gao <[email protected]> Contributed-under: TianoCore Contribution Agreement 1.0 Signed-off-by: Dandan Bi <[email protected]> --- MdePkg/Library/UefiDevicePathLib/DevicePathToText.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/MdePkg/Library/UefiDevicePathLib/DevicePathToText.c b/MdePkg/Library/UefiDevicePathLib/DevicePathToText.c index 7d8d304f6f..85f5e97131 100644 --- a/MdePkg/Library/UefiDevicePathLib/DevicePathToText.c +++ b/MdePkg/Library/UefiDevicePathLib/DevicePathToText.c @@ -193,11 +193,11 @@ DevPathToTextVendor ( return ; } else if (CompareGuid (&Vendor->Guid, &gEfiVT100PlusGuid)) { UefiDevicePathLibCatPrint (Str, L"VenVt100Plus()"); return ; } else if (CompareGuid (&Vendor->Guid, &gEfiVTUTF8Guid)) { - UefiDevicePathLibCatPrint (Str, L"VenUft8()"); + UefiDevicePathLibCatPrint (Str, L"VenUtf8()"); return ; } else if (CompareGuid (&Vendor->Guid, &gEfiUartDevicePathGuid)) { FlowControlMap = (((UART_FLOW_CONTROL_DEVICE_PATH *) Vendor)->FlowControlMap); switch (FlowControlMap & 0x00000003) { case 0: -- 2.18.0.windows.1 _______________________________________________ edk2-devel mailing list [email protected] https://lists.01.org/mailman/listinfo/edk2-devel