Sergey:

  It means TextTwo in this opcode is not used. It can be removed. For example, 
the highlighted statement is unused. Now, VfrCompiler tool directly ignores it. 
The better code should remove it.

FrontPageVfr.Vfr:

    text

      help    = STRING_TOKEN(STR_CONTINUE_HELP),

      text    = STRING_TOKEN(STR_CONTINUE_PROMPT),

      text    = STRING_TOKEN(STR_NULL_STRING),  // TextTwo

      flags   = INTERACTIVE,

      key     = FRONT_PAGE_KEY_CONTINUE;



The warning message doesn't point to the source VFR file, because VfrCompiler 
tool doesn't support line format in GCC preprocess file. VfrCompiler could be 
enhanced.



Thanks

Liming

-----Original Message-----
From: Sergey Isakov [mailto:[email protected]]
Sent: Friday, October 03, 2014 4:31 PM
To: [email protected]
Subject: [edk2] Action opcode should not have TextTwo part



Hi sirs,

What is means this warning:

VfrCompile...

Bm.i(110): WARNING: 0x0002

                : Action opcode should not have TextTwo part Same in 
FrontPageVfr.i(40), FE.i(106) (112, 147, 153) I see no correlation between 
these digits (line numbers?) with real lines.

BaseTools and Vfr sources are most recent.



Sergey



------------------------------------------------------------------------------

Meet PCI DSS 3.0 Compliance Requirements with EventLog Analyzer Achieve PCI DSS 
3.0 Compliant Status with Out-of-the-box PCI DSS Reports Are you Audit-Ready 
for PCI DSS 3.0 Compliance? Download White paper Comply to PCI DSS 3.0 
Requirement 10 and 11.5 with EventLog Analyzer 
http://pubads.g.doubleclick.net/gampad/clk?id=154622311&iu=/4140/ostg.clktrk

_______________________________________________

edk2-devel mailing list

[email protected]<mailto:[email protected]>

https://lists.sourceforge.net/lists/listinfo/edk2-devel
------------------------------------------------------------------------------
Meet PCI DSS 3.0 Compliance Requirements with EventLog Analyzer
Achieve PCI DSS 3.0 Compliant Status with Out-of-the-box PCI DSS Reports
Are you Audit-Ready for PCI DSS 3.0 Compliance? Download White paper
Comply to PCI DSS 3.0 Requirement 10 and 11.5 with EventLog Analyzer
http://pubads.g.doubleclick.net/gampad/clk?id=154622311&iu=/4140/ostg.clktrk
_______________________________________________
edk2-devel mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/edk2-devel

Reply via email to