(Originally sent without a "Subject") I'm not sure whether this is a problem or not but after performing the S-meter alignment on p. 47 of the K2 assembly manaual, the tenth bargraph LED stays lit. It is lit whenever I turn on the rig. The AGC threshold is 3.80 Vdc at U2 pin5. I have completed Alignment and Test II with no problems or defects.
Thanks in advance for any helpful feedback. -Gary N0AGH _______________________________________________ Elecraft mailing list Post to: [email protected] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com