Hi all, In the K3 Assembly Manual Rev L, I reached the point of doing resistance checks on pages 44 and 45. Of the 4 checks all are fine except for U12. Instead of getting a resistance reading on my digital meter, it never settles down. It cycles through a range of values up through the Mohm range.
Does this sound like a meter issue or a problem? Thanks for any advice, Mike ab3ap Readings: Across 12 VDC IN: infinite (should be > 3 kohms) R36/gnd: 240 ohms (> 150 ohms) U13/gnd: 424 ohms (> 150 ohms) U12/+5V leg: cycles through readings U12/+12V leg: 240 ohms ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html