Thanks for curing my builder's paranoia, Ron. That's all it was. :-) Mike ab3ap
On Aug 3, 2010, at 11:18 PM, Ron D'Eau Claire wrote: > ...It sounds like > your meter is supplying enough voltage to start to turn some junctions "on" > so they draw more current resulting in a lower resistance, then your meter > switches ranges to one with less voltage and they again turn "off" and so > on. > > Try using a manually-selected fixed range and see how it acts. > > Ron AC7AC > > -----Original Message----- > [mailto:[email protected]] On Behalf Of Mike Markowski > Sent: Tuesday, August 03, 2010 7:57 PM > To: Elecraft > Subject: [Elecraft] K3 assembly, resistance checks > > ...Of the 4 checks all are fine except for U12. > Instead of getting a resistance reading on my digital meter, it never > settles down. It cycles through a range of values up through the Mohm > range... ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html