On May 10, 2005, at 10:36 AM, [EMAIL PROTECTED] wrote:

I recently assembled and XG1 calibrator and began checking some of my equipment. 4 out of 5 radios that I own indicated an S9 signal, however, my K2 did not. It registered an S5-S6. A friend of mine who borrowed my K2 indicated the receiver seemed to be a bit weak.

Is the receiver provably weak, or is the S-meter just stingy? The K2 receiver may be working just fine, you're S-meter may just be adjusted so that it is very stingy.

I had troubles with my AGC and S-meter on my K2. My notes are in the archives. <http://www.ac6rm.net/mailarchive/html/elecraft-list/2002-03/ msg00740.html>

I eventually figured this out. I changed R1 to 30.1 k (newer K2s are adjustable here) and picked D1 to be a diode with a higher Vf. These measures helped a little, after I re-adjusted S-HI and S-LO.

The real problem was that Q12 was bad. Since I didn't have a PN2222A, I substituted a 2N2222A (metal TO-18 package). It's been working great for a couple of years now.

Bill Coleman, AA4LR, PP-ASEL        Mail: [EMAIL PROTECTED]
Quote: "Not within a thousand years will man ever fly!"
            -- Wilbur Wright, 1901