Had never checked the power out for my KPA-100, so did so. Took the KAT-100
out of the chain for the test, using dummy load. Startled by the results:
band K2 KPA-100 KPA-100
thru ATU no ATU
160 ------- 10.7 ---------100 --------- 100
80 ------- 15.0 ---------100 --------- 100
40 ------- 14.1 --------- 90 --------- 90
30 ------- 14.2 --------- 80 --------- 80
20 ------- 14.5 --------- 50 --------- 50
17 ------- 14.4 --------- 60 --------- 60
15 ------- 14.5 --------- 60 --------- 60
12 ------- 14.1 ---------100 --------- 40
10 ------- 14.7 ---------100 --------- 25
Dunno what to make of it.
73
Fred
kt5x