While we are on the subject of toroids, I would like to point out something I 
have encountered while up-grading pre-built K2's... Toroids can be wound 
backwards, and when this is done to vertically mounted toroids, the wire leads, 
as they exit the center of the core, are on the wrong side of the toroid...The 
"fix" is to pass the wire under the core to the other side so it reaches the 
solder pad...This adds another turn to the toroid, 1/2 a turn at each 
end...Also, the toroid is not secure and is free to move around which might 
result in wire fatigue, especially in a portable, mobile, or back-packing 
environment where vibration is present...

One of the radios I up-graded had evidently been dropped and landed upside 
down...The miswound toroids were standing up off the board by about 1/2 inch 
and had rotated 1/2 turn because the wires were pulled taut by the G force...

If a toroid has been wound backwards, it is best to strip it and rewind it 
correctly...

Jerry, wa2dkg
_______________________________________________