Al,

Yes, the solder reflow should fix it. relay K15 must have a path to K14 
before K13 is connected, and K13 then connects C72 for 80 meters - the 
whole path must be intact.
Sounds like you got it.

73,
Don W3FPR

On 9/6/2011 11:16 AM, Alan Davenport wrote:
> Don,
>   
>      No, the relays are not damaged. I was extra careful with them as the 
> build instructions said to be.
>   
>       I just re-flowed the solder on C72 and all K13 pins. The rig is now 
> working on all bands and the VCO is in spec on all bands EXCEPT 80m. 80 was 
> working briefly and just quit as I was typing my response. I switched bands 
> and when I switched back to 80 it was dead again. Direct frequency entry does 
> not help.
>   
> I  think I had two seperate issues. 80M had been dead since I was away on 
> vacation this June and the other bands were working fine. I do not know when 
> they went dead but I do know I spent 7 weeks at a remote cabin and I used the 
> K2 extensively on all bands up there. 80 went dead while I was there. (3 days 
> after I put up a dipole to get on a net!)
> .....
>   
> I just took it apart again, I reflowed the solder on all relays for 80m, 
> K2,K3,K8,K13 and also K14&  K15 as well while I had it apart. 80m is 
> currently working as are all other bands. I have switched bands many times 
> and 80m continues to work. Looks like I may have fixed it with your help. As 
> always Don, thank you very much for taking the time to help me and everyone 
> else who asks for help.
>   
>      Take care,
>    Al, W2GZN
>
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to