Any progress in this area? I'm experiencing the same problem. KPA500 s/n 468 fw v1.11 with BAND CHG set to STBY K3 s/n 495 fw v4.42 with PWR SET set to PER BAND
Works correctly when using band change up/down buttons on K3 but when using band change buttons on KPA500 the power setting for OPER remains in effect after the change - the STBY power setting is not recalled. Bob NW8L This _was_ fixed in the V1.11 firmware. I will be contacting you off-list to get more details to determine why it may not be working in your setup. Jack Brindle, W6FB Elecraft Engineering On Sep 25, 2011, at 11:01 AM, Richard Squire - HB9ANM wrote: > On July 1, I wrote: > "When BAND CHG is set to STBY (which I prefer in order to avoid tuning my > dipole on the new band with 400 W instead of 20 W by mistake!), the KPA500 > does go into STBY when changing bands but the K3 keeps the lower power > setting and does not return to 100 W. This does not happen if BAND CHG is > set to NOR." > > This was supposed to be a timing problem to be resolved with the next FW > release but FW 1.11 didn't solve it. Any one else noticed this? > Not a big issue but I'd like to go for BAND CHG = STBY... > Anyway, the KPA500 is joy to use. > > 73 > > ----- > Richard - HB9ANM ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:Elecraft@mailman.qth.net This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html