Mike,
1A hex = 26 decimal not 25.
Gary
N6LRV

-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of Mike
Morrow
Sent: Monday, August 06, 2012 5:24 PM
To: [email protected]
Cc: [email protected]
Subject: [KX3] Re: KX3 Operating Tip: Determining the ATU's L/C values and
L-net configuration

For Wayne's example of AK031A01:

The ATU inductance byte is 03(hex) = 003(decimal).
The ATU inductance thus is 3 x 0.0622 uH = 0.1866 uH.

The ATU capacitance byte is 1A(hex) = 025(decimal).
The ATU capacitance thus is 25 x 10.48 pF = 262 pF.

73,
Mike / KK5F