Jeremy,

I have read your exchanges with Gary,

First, don't bother with the C22 setting - just set it to the midpoint (slot parallel with the long edge of the board) and leave it there until you have the rest of the K2 receiver working on all bands, and then go to my website www.w3fpr.com and do the procedures stated in the K2 Dial Calibration article there.

Taking things one step at a time - is the PLL Range correct at TP3? Tap BAND+ to bring it to the highest frequency (about 12100 kHz) then tap BAND- to get to the lower limit (about 12087 kHz) Those frequencies can vary by 2 to 3 kHz from the target values and still be OK.

Once assured that the PLL Range is correct, then tackle the VFO frequencies.
You do have something wrong there because your frequencies are too low on all bands. That indicates either too much capacity or too much inductance is present in the VFO circuit. Look at the schematic for RF Board sheet 1. The area in question is in the upper right corner - the input side of Q18 - as well as the VFO range Select components.

Is T5 wound on a yellow core? If wound on a red core, it will have too much inductance. Does L30 have a slot across the entire diameter of the tuning slug? It should. Look at the tops of D23, D24, D25 and D26. They should have a top shape like Q18 and about the same size. D21 and D22 should have a smaller body profile when viewed from the top. The wider flat side of all those varactors should be facing toward the rear of the RF Board.

Your next step is to check the relays K13, 14 and 15. The white stripe should be on the end toward the rear of the RF board.

Examine the bottom of the board for the soldering of those components in the VFO and VFO Range Select areas to be certain there are no tiny solder bridges.

If everything is correct, it *should* have close the frequencies listed in VCO Table on the Schematic Key page - within 3 to 5 kHz when everything is correct.

73,
Don W3FPR



On 2/2/2013 9:43 AM, JeremyJones wrote:
I'm in the process of building a K2 and am having trouble at the Alignment
and Test part 2.  I've gone through at ton of previous posts here an have
been talking with Gary at Elecraft but no luck so far.  The main issues are
C22 only has adjustment less than 1khz (12085-12086) @ TP3, and R30 which
should have 6V only has 0.02V.

Below is the email chain (bottom to top) with the trouble shooting Gary and
I went through.  Wonder if anyone has any ideas of what the issue might be,
or further trouble shooting steps to isolate the problem.

Thanks,
Jeremy



______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to