Jeremy,
The problem of HiCur coupled with low power output is usually associated
with a problem either in T4 or the Low Pass Filter.
Check all the capacitors in the Low Pass Filter for proper values and
count the turns on the toroids. Count only the turns passing through
the center of the core. It is easy to put an extra turn on the toroids,
and the result is a HiCur message along with low power output.
73,
Don W3FPR
On 3/5/2013 7:58 PM, JeremyJones wrote:
I'm trying to complete the stage 3 transmitter alignment on my K2 and have
run into a bit of a snag. The 40M check looks good according to the built
in power meter, however with an external watt meter connected to a dummy
load, I am getting less than 1W on the with the K2 set at 2W, and about 2W
when set for 10W. Moving on to 80M at 2W I get a high current warning.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]
This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html