Hi
Just an update on the no power  problem I reported last month.
After checking a series of RF voltages using a checklist from Gary I located the problem as no RF from the KREF3 board at J65 I then removed the KREF board and all the cables, inspected board and re assembled the KREF3 and reinstated the cables.
Since then the problem has not recurred.
So it could have been a poor contact on the KREF3 cabling. It was not downstream of the KREF3

73 and thanks to Gary

Bob G3PJT