Hi
Just an update on the no power problem I reported last month.
After checking a series of RF voltages using a checklist from Gary I
located the problem as no RF from the KREF3 board at J65
I then removed the KREF board and all the cables, inspected board and re
assembled the KREF3 and reinstated the cables.
Since then the problem has not recurred.
So it could have been a poor contact on the KREF3 cabling. It was not
downstream of the KREF3
73 and thanks to Gary
Bob G3PJT