I've got the K3/KAT500/KPA500 all chained together with the Elecraft DB15 accessory cables.
I'm now in the process of connecting up the PR6/DIGOUT1 enabling line. I've removed the jumper in the PR6 and connected the control signal to the PR6 to DIGOUT1 and all works well; switching the CONFIG: DIGOUT1 menu entry causes the relays in the PR6 to switch audibly. However when I connect up the DB15 chain to the KAT500 the DIGOUT1 line is permanently pulled low. Referring to the cable diagram and the KAT500/KPA500 connector callouts it appears the KAT500/KPA500 use the same PIN11 as DIGOUT1 for an INHIBIT# function. I disconnected the KPA500 from the chain and the KAT500 appears to be pulling this line low all the time. Do I need to remove PIN11 from the cable as well? I already have the Keyline interrupter installed which has PIN10 removed. Confused... jim ab3cv ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[email protected] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html