Hi Josh,

I think you are right, am no native english speaker but I think that is the 
better way to read it.

In my understanding, the main purpose of the ALC is to reduce the power drive 
to keep the plate oder grid currents from being driven into the non-linear 
region in order to prevent non-linear distortions (splatter, harmonics). 

 Maybe the levels are such that, with ALC on, the drive power would already be 
reduced before the max.  output power is reached? This would explain the 
recommendation (in your reading) if the main limitation is a "thermal" one 
instead of a "non-linear" one.


Vy 73

Ralf, DL6OAP