Yes and no.  When you switch the mains power back on, the microcontroller 
should recognize the front panel power button press and be able to connect to 
software via its serial port.  The KPA Utility should be able to reconnect; use 
its port tab "Test Communications" button.  If the KPA500 has mains power, the 
Utility should indicate that the Amp is ready for firmware load or power on.  
After that reconnection, the KPA Utility Operate tab has a power button that 
should simulate pressing the Amp front panel power button. 

73 de Dick, K6KR

> On Jan 13, 2014, at 17:29, "Ron Leech" <[email protected]> wrote:
> 
> Can Some one tell me if the KPA500 sould come back on if the 220v power was 
> turned off then back on. My amp has on ocation locked up using it remote so I 
> wired a relay to turn it off with the radio and back on when the radio is 
> turned back on but the amp still reqires that I switch it back on.Should it 
> come back on with the ac power by it self or can it be made to come on. 
> 73s va7mv  Ron Leech 
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[email protected]
> 
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to