Stewart,

See page 44 of the manual. You cannot simply strap between ACC pins 5 and 8 - that connection must be removed after the power off command is sent.

73,
Don W3FPR

On 2/5/2014 9:49 AM, Stewart Bryant wrote:
I have a K3 that I wish to operate remotely.

I am happy to leave it running all the time, but I have a
computer controlled mains relay on the input of the PSU that I can
use to power cycle it if there is a problem.

Can I just put a link between pins 5 & 8 of the aux plug and
power on/off via the PSU mains?


______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to