Jeremy,
Remove the tuner and you will not be bothered with the LowP messages.
In fact when testing the base K2, you should remove the tuner and
operate the basic K2 into a dummy load.
Where are you measuring 600mV? That is one problem with replying using
Nabble, it strips off what you are relying to and only Nabble users can
make sense of things. I choose to download directly from the Elecraft
list as email, so some hint of the history is helpful.
73,
Don W3FPR
On 2/16/2014 4:05 PM, JeremyJones wrote:
I'm still getting 600mV and LowP during the tune, so it looks like I'll be
replacing Q11 and Q13 as well.
--
View this message in context:
http://elecraft.365791.n2.nabble.com/K2-Won-t-power-on-tp7584083p7584328.html
Sent from the Elecraft mailing list archive at Nabble.com.