The power delivered to the load really is forward power minus reverse power. You can see that by imagining that you disconnect the load completely (infinite impedance) or short it out (zero impedance). That means no power can be absorbed by the load.

The wattmeter reads equal forward and reverse power, so that forward minus reverse equals zero, as it must.

Alan N1AL



On 01/13/2015 12:45 AM, David Woolley wrote:
As well as not all the reflected power being re-reflected, the forward power measured by the coupler is not the first time forward power, but the sum of all the re-reflected power, as well.


______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]