"I would like the W2 wattmeter to be able to display "delivered" power, that is, forward power minus reflected power. This would give a more accurate indication of power going to an antenna when the SWR is not 1:1. For example, if the SWR on the line is about 2.5 and forward power indicates 1.2 kW, there is about 200 watts reflected power. In that case only about 1 kW (less line losses, of course) is being delivered to the load. It is misleading to look at just forward power."

Actually, "delivered power" is pretty much what you are measuring. Remember that reflected power is re-reflected by the source and adds back into the forward power. So in your example, you are transmitting 1200 watts, having 200 watts reflected, then the 200 watts is re-reflected by the source giving you the 1200 watts. Of course, there will be transmission line SWR-related losses.

Phil - AD5X

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[email protected]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [email protected]

Reply via email to